Next, thread the new pressure switch onto the water pipeby hand at first, then tightening with a wrench hold holding the standpipe with locking pliers. From the foot valve at the bottom of the well to the faucet at the sink, every piece of a well system is your responsibility to keep running efficiently. Reset it if needed. Your pump runs, but it cycles on and off repeatedly. You could be having other problems with your well system as I outlined in this post. Keep hazardous chemicals, such as paint, fertilizer, pesticides and motor oil, far away from the well. Pull the contacts apart and dislodge the internal spring. 0000025752 00000 n
Flip the breaker to the pump switch and check it with a voltage sniffer to make sure its off. Remove the small nut from the cover to gain access to the switch. margin-left: 10px;
Slap your adjustable wrench around the flats on the gauge and unscrew it.
Do not forget the ground connection. With a cordless screw gun or a manual screwdriver, turn out the screws holding the electrical wires to the contact points. 7 0 obj All that is left now is to reapply the cover and to open the gate valve of the water line to the dwelling. There are 3 main pressure switch settings. 2022 iFixit Licensed under Creative Commons Privacy 0000024701 00000 n Diagnose a cranky switch by rapping on it with a screwdriver handle. Keep your eyes on the pressure tank. endstream The switch needs to be replaced. Pump It Up Pump Service, Inc Apply about 6 wraps of Teflon tape on the threads. Go to the circuit breaker and switch off or remove the breakers that feed the well pump. It became immediately obvious that the nipple was almost completely corroded of the check valve. Connect the power wires and the pump wires as directed. A pressure switch can sometimes merely be sticky. Have your drinking water tested if there is a change in taste, odor or appearance, orwhen thewell system is serviced. Next drain the tank and the supply line by opening the valve. Once you know that it hasnt been switched off, check the circuit breaker to see if it has been tripped. If the switch does close, you can turn the power back on. document.querySelectorAll('#product_just_stars > .ind_cnt ')[0].innerHTML=(''+jumHtml+''); Electricity can be very dangerous, especially if you are inexperienced. Fax: (602) 254-2261 Also, wear eye protection when working on your well pump pressure switch. You may need to adjust the cut-in pressure (the point at which the well pump turns on) and the cut-out pressure (the point at which the well pump turns off). But how do you know for sure that your issue is the pressure switch?
Before repairing, replacing, or even examining the switch inside its housing, be sure to turn off the power to the pump at the electrical service panel. Connect the wires back as they were. A pressure switch is responsible for turning the well pump on and off as the water pressure inside the pressure tank changes.
Monday Friday: 7:00am 3:00pm. Also buy a new pressure gauge (less than $10) and a 1/4-in. If it happens to you, you will know what to do. Vol. If either are present, the contacts are bad. q{rAzQF6B,^Ks$i0?A%76]"f2[ BW3$"2Sgg+tE6mTv aqx'DqvjSTXZ\B-v\$O# a While buying a new pressure switch, you need to know its cut-in and cut off pressures. Given the low cost of new well pump pressure switches and the ease of installation, many owners find it more prudent to entirely replace the switch than to repair it. Choose a size and copy the code below to embed this guide as a small widget on your site / forum. endobj If you don't, you and the room will be showered with water at the first turn of a wrench. Make sure to buy a new switch that matches the old onethe rating is usually printed inside the housing of the switch. Empire Pump Corp dba Duncan Pump <>
If indeed you had a faulty switch the water pressure problem will have been resolved. You'll likely be able to if the toilet tank is full -- but only once. It could jeopardize the sanitary protection of your well. var jumHtml=""; 9 0 obj font-size: 13px !important; 0000026326 00000 n
endobj Next, remove the old switch (Photo 2) and gauge (Photo 3). You may be looking to increase pressure for one of the following reasons: the preset range does not provide satisfactory pressure when the water reaches your home, your shower/faucets are lacking sufficient pressure, or your sprinkler heads require a higher pressure. po.src = 'https://apis.google.com/js/plusone.js'; Don't allow fertilizers or pesticides to flow back into your well. Very inconveniently, your well pump pressure switch has ceased to function. Your old pressure switchs cut-in and cut-off pressure will be written underneath its cover. Remove the cover and test if indeed power to the pressure switch has been cut off using the voltage tester/multimeter. Now that you know how to tell if your well pump pressure switch is bad, you can rest a little more easily. Using an air compressor, add compressed air to the tank to bring it up to the correct pressure. Once you have removed the switch's outer housing, check again for the presence of electricity with a voltage tester. Close the valve from the pressure tank to the house. Replace it with a new one (about $24 at rural home centers and amazon.com). HTn@s*w6ZEjKS0,61f _]SWj[vyy `->=pkp1I#(N]cU7s[kAH'~@{^gm`%bWs d'R'1c Some switches have the contacts labeled as L1&L2 for the power lines and T1&T2 for the pump wires. The power supply to the pump is 220240 Volt and 20A. Better still unplug the pumps power cord from the electrical outlet. 8 0 obj You should always check the pressure when the tank is empty. <>/Font<>/ProcSet[/PDF/Text/ImageC]/Properties<>/XObject<>>>/Rotate 0/Type/Page>> 0000027005 00000 n Operating properly, this switch keeps the home's water supply at a uniform pressure at the taps. Check the pressure reading. The bottom one is the corroded one and the top is the new one.
The first thing before doing anything is to flip the breaker to the pump switch and check it with a meter to ensure it is off. And basically that is how to replace a well pump pressure switch. Maintain proper separation between your well and buildings, waste systems or chemical storage. Use a wrench to grab the pressure switch locknut and loosen it by turning it counterclockwise. Here is the inlet to the pressure switch. That will help you later in remembering exactly where each wire was connected. If the switch doesnt close and the water pressure remains low, the switch needs to be repaired. In this case the nipple needs to be replaced as well. The pressure tank should be set at 2 PSI less than the cut-on pressure. <> 7 45 endstream To make sure the water keeps flowing, we'll be changing the water pressure switch on our well, too. When landscaping, keep the top of your well at least 1 foot above the ground. When the pressure drops, the switch may fail to close. Wires, especially stranded wires, are greatly compromised when they are turned counter-clockwise. Install the new switch, connect the wires and turn power to the pump back on. If you are not 100% confident you can perform any of these tests safely, call a professional. Email: info@PumpItUpPump.com , which relies on a steady supply of water, our house would have no heat. While the above is a general statement of how you would do it, there are more steps involved as I will clearly show you in the rest of the post.
Check the nipple standpipe on which the pressure switch rests. 0000001439 00000 n
If you attempt to replace the switch, don't forget to first warn your family -- unless you get some warped sense of pleasure in hearing their anguished cries when they try to quench their thirst or flush the toilet.
Registration on or use of this site constitutes acceptance of our User Agreement, Privacy Policy and Cookie Statement, and Your California Privacy Rights (User Agreement updated 1/1/21. Use a suitable wrench like an adjustable or in this case a pipe wrench. You can as well go an extra step and mark the wires with a pen before taking the picture.
Before disconnecting the pressure switch, you will first need to completely drain the tank. 7. 17 0 obj More than 34 million homes in the U.S. get their potable water from in-ground wells rather than from a municipal water supply. An awesome member of our community made this guide. It is a relatively quick and easy fix, so you can soon get back to your hot morning showers. Your Well Water Is Yellow? document.getElementById( "ak_js_1" ).setAttribute( "value", ( new Date() ).getTime() ); Plumbing Sniper is a participant in the Amazon Services LLC Associates Program, an affiliate advertising program designed to provide a means for sites to earn advertising fees by advertising and linking to Amazon. 0000085301 00000 n
A professional plumber will however charge you upwards of $100 depending on your area. With the new pressure switch in place, turn on power to the pump. Monday Friday: 6:00am 3:00pm endobj We recommend our users to update the browser. Open the shut off valve to the house plumbing. 0000009728 00000 n
Load of dirty dishes or laundry to do? This helps in creating a good contact. bJg@tp.`}1U! endobj
10 0 obj endobj Replacing or servicing the pump pressure switch is usually an easy enough DIY project, but if the pipe fittings or standpipe that holds the pressure switch seem badly corroded or otherwise damaged, it's best to call a well pump specialist to deal with the problem. After sufficient water has filled the tank, the pressure switch turns the pump off at the cut-off pressure. Read it here. },3000); Copyright 2022 R.C. Refer to the photo you took earlier and connect back the wires on the terminals. Using a nail file or emery board, clean off and smooth out the burnt or pitted areas. Community Rules apply to all content you upload or otherwise submit to this site. Household water systems often are pressurized at 20-40 pounds per square inch (psi) or 30-50 psi.
If you find that water is leaking internally, the switch is bad. }; You can either bleed off pressure from the tank or add more using an air compressor or bicycle pump. Thoroughly clean out the switch either with a shop vacuum or by blowing out the debris with an air compressor.
Your pump doesnt turn on at the proper cut-in pressure. Close off the water supply to the dwelling by turning the gate valve to the right side. ]2SHi94jL7p[B,t6F:vR|xmB"cA`NGk=7X3kuVrZVnz4+Y|*#Y5]]MJ-w%w]S+LED&Q,y
*4'U!KB$wmPCA-/8@SXRjv+LP|E` =yR_K"]&3Tun;Aly_TwIOAv uQr8?AYWQt'(
l}
You can also adjust the pressure differential by either increasing or reducing the cut-off pressure. Oh no!
0000025284 00000 n
this is what most likely caused the pressure switch to fail. The starting and stopping of a well water pump is typically controlled by a pressure switch similar to the one shown below. 0000002023 00000 n
Click here to see a video: How to Check and Adjust Pressure Tanks or click here to read a blog: How to Check and Adjust Your Pressure Tank. As you tighten the connections later, you want the screws to grab the wires tightly. Two small nuts in the switch mechanism can be tightened or loosened -- depending on whether you want the pump to start or stop at a higher or lower pressure. })(); Empire Pump Corporation, formerly known as Duncan Pump and established in 1946, is a commercial water well pump company in Phoenix Arizona that specializes in the installation and rehabilitation of water well pumps and systems no matter whether your system is residential, commercial, industrial, municipal, environmental, mines, or agricultural. x 6-in. They'll have to wait. This caused problems since the excessive pressure caused some faucets to start leaking. Pressure switches therefore have 2 pressure settings, a lower one and a higher one. Worst & Company Inc. - All rights reserved. Open a faucet close to the pump. Remember how the wiring attaches so you can properly connect it to the new switch. Use a small pipe wrench to fasten it. Covering a Well Pump: Should I Cover My Well Pump? //jQuery(window).scrollTop(jQuery('#shopper_review_page').offset().top);
When we moved to our home outside the city limits, we knew little about water wells, let alone something called a water pump pressure switch or well pump switch. Check the metal contact points that open and close, thus triggering the system off or on, respectively. Replacing the pressure switch is cheap and takes only about an hour. You have low water pressure even though the pump is running. It is therefore paramount that the first thing you do is to turn off power to the well pump to prevent electrical shock. However, be sure to consult the manufacturer's instructions for information specific to your system. if(document.querySelectorAll('.sa_jump_to_reviews')!=undefined && document.querySelectorAll('.sa_jump_to_reviews')!=null && document.querySelectorAll('.sa_jump_to_reviews').length > 0){
Before doing anything however, I would recommend that you grab your phone or a digital camera and a take a picture of the connections. When the switch gives out, it usually does so in the "off" position, leaving you without water. Phone: (623) 582-5069 After taking the picture, loosen the screws and pull out the wires. lang: 'en-US' This is potentially deadly. If necessary, gently pull out the debris with a soft brush, such as an old toothbrush. We are no longer supporting IE (Internet Explorer) as we strive to provide site experiences for browsers that support new web standards and security practices. Make sure that the drain valve at the bottom of the tank is turned off.
Such is the nature of mechanical components. Often, this is between 2 and 4 PSI below the switch's lowest limit, also called the cut-in limit. It seems that any plumbing job has some additional challenges, just like this one did. Look for the breaker marked Well Pump on your main electrical panel and flip it to the off position. After everyone has been notified and preparations have been made, shut off power to the switch. Decision was made to replace the switch. setTimeout(function(){
Periodically check the well cover or well cap on top of the casing (well) to ensure it is in good repair. It is not managed by iFixit staff. For Residential Services:
Thirsty? Note: As I mentioned earlier, you will need to feed the wires in such a wire that they curl around the screw from the left (clockwise) and not the right side. Amazon and Amazon logo are trademarks of Amazon.com or its affiliates. Don't forget to shut off the power before making any adjustments. Direct the other end of the garden hose out into the driveway, yard or floor drain. Pressure switches typically are available in three pressure ranges: 20 to 40 psi, 30 to 50 psi, and 40 to 60 psi. }
<<49494C12D21DB2110A00FFF68030A6FF>]/Prev 216814>> What Size Pump Do I Need For My Water Well? The material on this site may not be reproduced, distributed, transmitted, cached or otherwise used, except with the prior written permission of Advance Local. 0000002296 00000 n
Because it gets so much constant use, the pressure switch is the most common failure point for a well pump. 0000005255 00000 n
Otherwise, these systems will fill with air instead of water, and you could find yourself replacing more than just a pressure switch.
Note to readers: if you purchase something through one of our affiliate links we may earn a commission. <>stream
Note: Do not forget to turn off or bypass water filtration equipment to prevent them from being clogged up by sediment. As you can see, there is usually a 20 psi difference between the cut-in and cut-off pressure. No spark? Weekends: Emergency Service Calls Only. Apply some thread sealing tape before installing the new nipple.
When the water pressure drops to a certain level, the switch senses more water is needed, and spring-loaded electrical parts make contact, turning on the well pump. Thread in the new pressure switch, starting off slowly to avoid cross threading. Having said that, I should also add that a pressure switchs cut-in and cut-off pressures can be adjusted as shown in this post. The signs of a faulty pressure switch are exhibited by a continuously cycling pump, low water pressure or a pump that does not start, meaning no water in the house. Remove the cover on your pressure switch. Adjusting the range can be done by following a few simple steps. 4I_=t[t1hF&T}w
Then screw in a new one and tighten it down. As you already know, the pressure switch turns the pump on and off when the water pressure in the tank changes. HTo0_q^` If lightly rapping on the switch causes the pump to turn on, then it probably just needs disassembly and a good cleaning to return it to good working order. Factory presets can be found inside the cover of the pressure switch (as shown on right above). 2849 S 49th Ave Phoenix, AZ 85043 16 0 obj Clamp locking pliers on the lower nipple standpipe to keep it from rotating. If you adjust your cut-on pressure you will also need to adjust the pressure tank air charge. If you are accustomed to wiring household outlets and ceiling lights, you have the basic know-how to disconnect and reconnect wires on a well pump pressure switch. The Spruce uses only high-quality sources, including peer-reviewed studies, to support the facts within our articles. On the other hand if the problem persists, you may be having a faulty well pump. However, a few simple repairs may keep your well pump pressure switch running longer. Things You Must Know About Well Maintenance Near Me, Common Problems You Might Find With Your Residential Well, Well Water Drilling vs Well Water Maintenance, Buying a Home With a Well? WARNING: The switch is supplied with 220V so one has to be careful not to get zapped.
ResidentialCommercialIndustrialAgriculturalEnvironmentalMunicipal, Subject Line of the email you are about to send, For Commercial Services: 14 0 obj When the pressure returns to a preset level and the well tank is filled, the electrical contacts separate, and the well pump turns off. Then unscrew the conduit locking ring and pull the wires and conduit out of the switch.
Youll have to deal with it when you get home. The tap will be dry. 0000028207 00000 n
0000010130 00000 n
jQuery('.sa_jump_to_reviews').click(function(){
Here is a time lapse of what the pressure gauge showed. You will turn the nut counterclockwise to lower both cut-on and cut-off pressure or turn the nut clockwise to raise both cut-on and cut-off pressure. Clean the water pipe's threads of any old pipe sealant or pipe seal tape. This will take a few minutes. This time round you will need to start with ground connection since it is at the bottom. Replace with new parts. Adjusting the differential will only adjust the cut-off pressure. xref The gauge is an inexpensive part ($10 to $15) and is simply screwed into the pipe fitting leading to the pressure tank. This fix wont last long, but it can buy you some time until you can replace the pressure switch or call in a well pump repair professional. After turning off the power to the pump at the main service panel, use a manual screwdriver or screwgun to loosen the screws that hold the pressure switch housing in place. 0000022096 00000 n
Reconnect the wires to their contacts and screw them down tightly. Electrical power runs through your well pump pressure switch. We've updated our Privacy Policy, which will go in to effect on September 1, 2022. We found out one bright October morning when my wife discovered a 7-foot flame lapping at the basement ceiling. 51 0 obj
Phone: (602) 254-6154 Again visible is the large amount of corrosion and debris from the corroded nipple. As a temporary fix, pull the metal discs apart (after double-checking that the power is off). Loosen the 4 screws that hold the wires to the switch. Install the wiring, close the faucet and repower the pump. Note: It is very important to check how the wires enter the pressure switch opening. If your well pump pressure switch isnt functioning, give us a callat 623-582-5069 today and well be happy to fix it for you! 6 Ways To Use Baking Soda To Clean Your Pool, Do Not Sell My Personal Information CA Residents. Pull the metal discs apart to check for burns and feel for pits. Install the nipple into the check valve. Email: info@EmpirePumpInc.com 26, No. The cut-on pressure is the low pressure that starts the pump and the cut-off pressure is the high pressure that turns off the pump. By the DIY experts of The Family Handyman Magazine. <> }
While a steady supply of fresh water is the principal reason to regularly replace the water pressure switch, there's also another reason -- safety. Then disconnect the wiring (Photo 1). jQuery('body,html').animate({ scrollTop: jQuery('#shopper_review_page').offset().top }, 800);
Read our, How to Repair a Well Pump Pressure Switch, Examine and Clean the Electrical Contact Points, How to Replace a Well Pump Pressure Switch, Turn off the Power and Remove the Pressure Switch Housing, Reconnect the Wires and Replace the Housing, Troubleshooting Checklist for an Electric Water Heater, Replacing a Heating Element in an Electric Water Heater, When Your Oven Stops Heating, You May Be Able to Fix it Yourself, How to Fix or Replace a Ceiling Fan Chain Quickly, Create Versatile Lighting Effects With a Dimmer Switch, How to Replace a Main Water Shutoff Valve, Learn How to Install a Handheld Showerhead. Always use caution working with electricity and turn off power supply breakers when testing components or making any adjustments within the electrical system. endstream Also shut off power to the water heater, the automatic sprinkling system -- anything that automatically draws water. You need to replace the switch. Heres how to tell if your well pump pressure switch is bad. endobj -- or should be.
And if you're on that last pair of clean underwear, the washing machine will be at your service.