disintegration tester parts

JavaScript seems to be disabled in your browser. Mass spectrometry, chromatography, spectroscopy, software, dissolution, sample handling and vacuum technologies courses, Live or on-demand webinars on product introductions, applications and software enhancements, Worldwide trade shows, conferences, local seminars and user group meetings, Service Plans, On Demand Repair, Preventive Maintenance, and Service Center Repair, Software to manage instrument access/usage, sample processing, inventories, and more, Instrument/software qualifications, consulting, and data integrity validations, Learn essential lab skills and enhance your workflows, Instrument & equipment deinstallation, transportation, and reinstallation, CrossLab Connect services use laboratory data to improve control and decision-making, Advance lab operations with lab-wide services, asset management, relocation, Shorten the time it takes to start seeing the full value of your instrument investment. You need JavaScript enabled to view it. The cookie stores information anonymously and assigns a randomly generated number to recognize unique visitors. Regular replacement of this tubing is recommended to prevent contamination. The user-friendly design makes assessing disintegration characteristics a simple touch-of-a-button task. var addy_text2889813ea28d288349f7262518a69a8d = 'info' + '@' + 'erweka' + '.' + 'com';document.getElementById('cloak2889813ea28d288349f7262518a69a8d').innerHTML += ''+addy_text2889813ea28d288349f7262518a69a8d+'<\/a>'; 115114 . disintegration testers vankel 25mm tubes assembly replacement plastic tube quote vankel disintegration testers

Disi AutoSense Disintegration Tester: Accurate, Intelligent, 21 CFR Part 11 Compliant. This website uses cookies to improve your experience while you navigate through the website. var path = 'hr' + 'ef' + '='; List, Isolation Technologies (IDEX Health & Science), Upchurch Scientific (IDEX Health & Science), QLA Disintegration Testing: 10 Mesh SS Screens for 6 Tube Disintegration Assembly, QLA Disintegration Testing: 10 Mesh SS Screens for 3 Tube Disintegration Assembly, Dissolution: Glass Replacement Tubes for 6 Tube, QLA Disintegration Testing: USP Fluted Disks for 3 Tube Disintegration Assembly, QLA Disintegration Testing: USP Fluted Plastic Disks for 6 Tube Disintegration Assembly, QLA Disintegration Testing: 900mL Clear Glass Disintegration Beaker with Flared Top, QLA Disintegration Testing: Glass Replacement Tubes for 3 Tube Disintegration Assembly, 38mm, QLA Disintegration Testing: 900mL Clear Glass Disintegration Beaker with Flat Top, QLA Disintegration Testing: Plastic Replacement Tubes for 6 Tube Disintegration Assembly, 25mm, QLA Disintegration Testing: Disintegration Basket Assembly with 6 Glass Tubes and 10 Mesh SS Screens for VanKel Testers, QLA Disintegration Testing: Disintegration Basket Assembly with 3 Glass Tubes and 10 Mesh SS Screens for VanKel Testers, QLA Disintegration Testing: Disintegration Basket Assembly with 6 Plastic Tubes and 10 Mesh SS Screens for VanKel Testers. The _ga cookie, installed by Google Analytics, calculates visitor, session and campaign data and also keeps track of site usage for the site's analytics report. dissolution agilent merel kapsul

The pattern element in the name contains the unique identity number of the account or website it relates to. A special sensor built into the base of the SmartBasket assembly continuously measures the temperature of the disintegration medium. var addybfa42b8edb5e9785a4b5de5c8462e3a2 = 'sales' + '@';

Phone: +1 (732) 662-1143E-Mail: This email address is being protected from spambots. Installed by Google Analytics, _gid cookie stores information on how visitors use a website, while also creating an analytics report of the website's performance. addy2889813ea28d288349f7262518a69a8d = addy2889813ea28d288349f7262518a69a8d + 'erweka' + '.' + 'com'; All QLA Products are manufactured to ISO9001 quality standards. User permissions and security settings are highly configurable and recorded by the software. These cookies will be stored in your browser only with your consent. These cookies help provide information on metrics the number of visitors, bounce rate, traffic source, etc. The user-friendly design makes assessing disintegration characteristics a simple touch-of-a-button task.

The fully programmable Agilent 100 automated disintegration apparatus provides a reliable, compliant approach to disintegration testing. addybfa42b8edb5e9785a4b5de5c8462e3a2 = addybfa42b8edb5e9785a4b5de5c8462e3a2 + 'erweka' + '.' + 'ru'; With the same standard features as the other DTGi Series testers and supporting up to 2 basket rack assemblies, the DTG 200i-IS offers independent control over each test station, making it ideal for the following types of applications: Integrated, precision temperature control and measurement, Single-point electronic temperature calibration, Intuitive touchscreen control to simplify operation, One to four test station unit configurations, plus independent station control unit option, Extensive data reporting output options: RS 232, USB A and USB B, Adjustable stroke frequency control for accelerated or high sensitivity testing, Option to automate and remotely control DTGi systems, For converting the standard basket to special covered version for testing hard or soft gelatine capsules accepting to USP Chapter <701>. All rights reserved|Registered in England and Wales under company number 4718736 and VAT number GB 702 1041 10, GL Sciences Columns Parts and Consumables, Glass Expansion ICP - ICP MS Parts and Supplies, Merck Hitachi HPLC Parts, Spares & Consumables, Varian VanKel Compatible Dissolution Products, Electrolab Compatible Dissolution Products, Lab India Compatible Dissolution Products, Pharmatest Compatible Dissolution Products, QLA 10 mesh Cover for 3 tube disintegration assembly, 316 SS, VanKel/Agilent and Distek compatible - DISASY-03COV10, QLA 10 mesh Cover for 6 tube disintegration assembly, 316 SS, VanKel/Agilent and Distek compatible - DISASY-06COV10, QLA 100 Mesh SS Screens for 6 Tube Disintegration Assembly (Set/6) - DISSCR-VK100, QLA 1000mL Clear Glass Disintegration Beaker with Flared Top for Distek Disintegration Model 3100 - GLA900-DBDK (3010-0360), QLA 20 Mesh SS Screens for 6 Tube Disintegration Assembly (Set/6) - DISSCR-VK20, QLA 40 Mesh SS Screens for 6 Tube Disintegration Assembly (Set/6) - DISSCR-VK40, QLA Glass Replacement Tubes for 3 Tube Disintegration Assembly for Hanson Testers, 38mm OD x 80mm L (Set/6) - DISTUB-HR03, QLA Glass Replacement Tubes for 6 Tube Disintegration Assembly for Erweka Testers, 24mm OD x 78mm L (Set/6) - DISTUB-EW, QLA Glass Replacement Tubes for 6 Tube Disintegration Assembly for Hanson Testers, 25mm OD x 79.5mm L (Set/6) - DISTUB-HR06, QLA Glass Tubes for 6 Tube Disintegration Assembly, Sotax compatible - DISTUB-ST06, QLA VisiChek Mirrored Acrylic Plate for Distek 7100 baths, 3 mm thick - MIRPLT-7100, QLA Basket Assembly, 6 Glass Tubes, 10 Mesh Screens, Varian VanKel Compatible - DISASY-06 (37-2001), QLA Basket Assembly, 6 Plastic Tubes, 10 Mesh Screens, Varian VanKel Compatible - DISASY-P6, QLA Glass Disintegration Tubes for 6 Tube Assembly, 6/Pk - DISTUB-06, QLA Plastic Disintegration Tubes for 6 Tube Assembly, 6/Pk - DISTUB-P6, QLA Disintegration Basket Assembly with 3 Glass Tubes and 10 Mesh SS Screens for VanKel Testers - DISASY-03 (OEM:37-3030), QLA USP Fluted Disks for 3 Tube Disintegration Assembly (Set/3) - DISDISK-03 (OEM:37-4010), QLA 10 Mesh SS Screens for 3 Tube Disintegration Assembly (Set/3) - DISSCR03-VK10, QLA 10 Mesh SS Screens for 6 Tube Disintegration Assembly (Set/6) - DISSCR-VK10 (OEM:37-2200), QLA Glass Replacement Tubes for 3 Tube Disintegration Assembly, 38mm (Set/3) - DISTUB-03 (OEM:37-5005), UVISON_ISS and LNI SWISSGAS Partnership for 2019, ISS Limited are on the move for the Summer of 2017. 2022 Vortex Sales Group All rights reserved. This category only includes cookies that ensures basic functionalities and security features of the website. var prefix = 'ma' + 'il' + 'to'; You can view our privacy policy. Please visit our service part section for more specialised tubing between hardware components. You need JavaScript enabled to view it. Phone: +49 6103 924 26-0 E-Mail: This email address is being protected from spambots. Pharmaceutical Testing Tablet Disintegration Testing.

93Bonham Strand Sheung WanHong Kong. var addy2889813ea28d288349f7262518a69a8d = 'info' + '@'; This email address is being protected from spambots. 16, 103 Phone: +7 499 110 90 60 E-Mail: This email address is being protected from spambots. But opting out of some of these cookies may have an effect on your browsing experience. The highly sophisticated electronics built into the SmartBasket assembly are protected by a watertight, corrosionresistant construction that allows for fast, easy cleaning and low maintenance. var addy_text3f73e5186264a4ec477fdfd005b535b3 = 'sales.asia' + '@' + 'erweka' + '.' + 'com';document.getElementById('cloak3f73e5186264a4ec477fdfd005b535b3').innerHTML += ''+addy_text3f73e5186264a4ec477fdfd005b535b3+'<\/a>'; 31 Northfield Avenue Edison, 08837, NJUnited States. The apparatus is available in a three-basket model and comes complete with accessories required to perform the standard USP disintegration test. Agilent Compatible disintegration accessories, Pharmatron/Secom disintegration accessories. The audit trail automatically generated by the system will assist in complying with 21 CFR Part 11, without the need for special training or manual intervention. Special basket-rack assembly for large tablets, capsules and boluses. ZT 120 light Series Manual Disintegration Tester, ZT 730 Series Automated Disintegration Tester. Keep your water bath free of bacterial, algal or slime growth with Aqua-Stabil. The Paddle over Disk is a modified version of Method 2 (Paddle Method) and is used for the determination of the drug release rateof, APPARATUS 6 - USP An alternative method for the testingof. ), the DTGi tester series is an affordable range of disintegration testers that complies fully with specifications defined in Ph. Comparing one formulation directly against another, Comparing the performance of a single formulation under different conditions, Assessing delayed release or enteric coated tablets where samples must be immersed for specified periods of time in different media, Allowing two users to run tests simultaneously, Certificate of compliance to Ph.

addy1925c8664e745e851437e17dd97a6ae6 = addy1925c8664e745e851437e17dd97a6ae6 + 'erweka' + '.' + 'com'; Baskets may be programmed to automatically lift out of the beakers upon completion of the test, Temperature controlwater bath temperature is controlled from the keypad, can be reached in minutes, and is continuously displayed on the front-facing LED panel, Compactthe system is designed to save valuable laboratory bench space, Compliantsystem and accessories meet current USP specifications for disintegration testing, Easy cleaningquick-disconnect fittings for easy water bath draining and cleaning, Optional printerrecords instrument test parameters and status at a predefined interval and delivers hard-copy printouts for efficient and accurate reporting. var addy3f73e5186264a4ec477fdfd005b535b3 = 'sales.asia' + '@'; Other uncategorized cookies are those that are being analyzed and have not been classified into a category as yet. You need JavaScript enabled to view it. Temperature and percent disintegration are displayed on the computer screen in real time while being automatically stored in the database for later retrieval and reporting in table and graphical formats. Standard tablets, capsules, and special products with multistage disintegration are all accurately monitored and documented. Some of the data that are collected include the number of visitors, their source, and the pages they visit anonymously. The ZT 730 series is the new generation of disintegration testers with automatic detection of disintegration time and innovative AirBasket technology. Out of these cookies, the cookies that are categorized as necessary are stored on your browser as they are essential for the working of basic functionalities of the website. Disintegration Basket Assembly with 3 Glass Tubes (38mm) and 10 Mesh SS Screens for VanKel Testers QLA Part Number: DISASY-03 Equivalent to OEM Part Number: Agilent 37-3030 Fits Bath Models: Agilent: VK100 Disintegration Cert of Compliance: Fluted Plastic Disks for 3 Tube Disintegration Assembly, USP/EP Compliant (Set/3) QLA Part Number: DISDISK-03 Equivalent to OEM Part Number: Agilent 37-4010 Fits Bath Models: Agilent: VK100 Disintegration Cert of Compliance: Yes Material: 10 Mesh SS Screens for 3 Tube Disintegration Assembly (Set/3) QLA Part Number: DISSCR03-VK10 Fits Bath Models: Agilent: VK100 Disintegration Material: 316 SS Screen Mesh: 10 UOM/Pack Size: SET/3 Additional Related Options: DISASY-03 - 3 10 Mesh SS Screens for 6 Tube Disintegration Assembly (Set/6) QLA Part Number: DISSCR-VK10 Equivalent to OEM Part Number: Agilent 37-2200 Fits Bath Models: Agilent: VK100 Disintegration Material: 316 SS Screen Mesh: 10 UOM/Pack Size: SET/6. Supplied with special cylindrical discs as specified in the Pharmacopoeia. Tubing is recommended for use with the Peristaltic Pump, syring pumps or any other fluidic path. var path = 'hr' + 'ef' + '='; Glass Replacement Tubes for 6 Tube Disintegration Assembly for Sotax Testers, 26mm OD x 79.3mm L (Set/6) QLA Part Number: DISTUB-ST06 Equivalent to OEM Part Number: Erweka 502-310-0001 Cert of Compliance: Yes Color: CLEAR Material: VisiChek Mirrored Acrylic Plate for Distek 7100 baths, 3 mm thick QLA Part Number:MIRPLT-7100 Compatibility:Distek 7100 baths. At 100% disintegration the system senses completion and automatically lifts the basket out of the beaker. The AutoSense system is controlled by Windowsbased client/server software. Controlled via our intuitive touchscreen interface, the DTGi 200i disintegration tester supports up to two basket rack assemblies. The user-friendly design makes assessing disintegration characteristics a simple touch-of-a-button task. addy3f73e5186264a4ec477fdfd005b535b3 = addy3f73e5186264a4ec477fdfd005b535b3 + 'erweka' + '.' + 'com'; document.getElementById('cloak1925c8664e745e851437e17dd97a6ae6').innerHTML = ''; These cookies track visitors across websites and collect information to provide customized ads.

These cookies do not store any personal information. The user-friendly design makes assessing disintegration characteristics a simple touch-of-a-button task. CleanTalkUsed to prevent spam on our comments and forms and acts as a complete anti-spam solution and firewall for this site. The ERWEKA ZT 121 light is the perfect entry-level disintegration tester. We also use third-party cookies that help us analyze and understand how you use this website. USP Monographs (Generic Drug Development), Aerodynamic Particle Size Distribution (APSD), Automated Shake, Fire and Flow Control for MDIs, Nasal Sprays and Aerosols, Suppository Disintegration Testing: SDT 1000, Vertical Diffusion Cell Test System: HDT 1000, Vertical Diffusion Cell Test System: HDT 1. A variation of the _gat cookie set by Google Analytics and Google Tag Manager to allow website owners to track visitor behaviour and measure site performance. Please select a DTGi Series tester for further product information, Quick-release baskets for rapid sample loading, unloading and cleaning, Intuitive touchscreen control with icon-based menu structure simplifies operation and clearly displays test parameters throughout run, Robust metal case with advanced corrosion protective coating, Basket rack assemblies are automatically lowered and raised to/from test media at start and end of test, Independent digital heater/circulator maintains a constant temperature and minimises vibration, Easily removable leak-proof water bath with convenient drain tap eases bath water emptying, PT100 temperature probe monitors bath and media temperature. var prefix = 'ma' + 'il' + 'to'; Grid var prefix = 'ma' + 'il' + 'to'; All rights reserved. You need JavaScript enabled to view it. var prefix = 'ma' + 'il' + 'to'; The Dissolution Source Book provides details on Agilents dissolution portfolio - dissolution apparatus, automated systems, calibration and verification tools, dissolution software, analytical UV-Vis and HPLC integration and physical testing. Our friendly and experienced team are here to help. WATCH VIDEO View Disi AutoSense Brochure.

The new Disi AutoSense from Teledyne Hanson Research delivers fully automated disintegration testing in compliance with USP <701> and <2040> and their harmonized EP and JP methods. PharmaTest offers a full range of Disintegration Accessories to comply with the latest chapters in USP <701> for Disintegration and USP <2040> Disintegration for Dietary Supplements. Designed for precision, productivity, and easeofuse, the Disi AutoSense provides a fast, maintenancefree solution for disintegration labs conducting tests in new product development and batch/lot manufacturing facilities. document.getElementById('cloak2889813ea28d288349f7262518a69a8d').innerHTML = ''; Plastic Replacement Tubes for 6 Tube Disintegration Assembly for VanKel Testers, 25mm (Set/6) QLA Part Number: DISTUB-P6 Fits Bath Models: Agilent: VK100 Disintegration Cert of Compliance: Yes Material: POLYCARBONATE UOM/Pack Size: SET/6. You must have JavaScript enabled to use this form. Controlled via our intuitive touchscreen interface, the DTGi 300i disintegration tester supports up to three basket rack assemblies. All our accessories are always in stock for quick deliveries. document.getElementById('cloakbfa42b8edb5e9785a4b5de5c8462e3a2').innerHTML = ''; var addy_text1925c8664e745e851437e17dd97a6ae6 = 'sales.usa' + '@' + 'erweka' + '.' + 'com';document.getElementById('cloak1925c8664e745e851437e17dd97a6ae6').innerHTML += ''+addy_text1925c8664e745e851437e17dd97a6ae6+'<\/a>'; Copyright 2022 ERWEKA GmbH. Advertisement cookies are used to provide visitors with relevant ads and marketing campaigns. Functional cookies help to perform certain functionalities like sharing the content of the website on social media platforms, collect feedbacks, and other third-party features.

14 January 2021; Nottingham, UK: Copley Scientific is now delivering e-Training, offering custome 01 April 2020; Nottingham, UK: Copley Scientific, a global supplier of pharmaceutical testing equ 6 February 2020; Nottingham, UK: Copley Scientific, a company renowned for high quality pharmaceu Understanding the links between drug delivery route and in vitro test methods 17 May 2016; Nottingham, UK: Copley Scientific, a family-owned company that began supplying glass Have a question? Performance cookies are used to understand and analyze the key performance indexes of the website which helps in delivering a better user experience for the visitors. Is there something you can't find, please feel free to contact us for custom work. You have no items in your shopping basket. Controlled via our intuitive touchscreen interface, the DTGi 400i disintegration tester supports up to four basket rack assemblies. Please review our privacy policy so you understand how we collect and use your personal data. We use cookies on our website to give you the most relevant experience by remembering your preferences and repeat visits. In this version, the six standard tubes are replaced with three tubes of a larger diameter (33 mm). document.getElementById('cloak3f73e5186264a4ec477fdfd005b535b3').innerHTML = ''; We offer a range of training courses, presentations and seminars, A comprehensive range of both in-house and on-site product servicing options are available, Our team of experienced technicians and engineers are on hand to help and advise. plain-coated tablets, delayed-release, gelatine etc. Contact Us Toll-Free: 800.260.0575 | eMail:sales@vortexsg.com. Teledyne Hansons precision beakers, manufactured to tightly controlled tolerances, are optimized for ease of compliance with USP guidelines. Chromatography & Spectroscopy Lab Supplies, GC Calculators & Method Translation Software, BioCalculators / Nucleic Acid Calculators, Dissolution Systems Source Book - 2020-2021 Edition, VK 100 Disintegration Apparatus Site Preparation Checklist, Efficientallows up to three different batches to be tested concurrently, and each basket can be individually programmed, Integratedintegrates the drive system, water bath, and heater/circulator with the test basket, eliminating the need for separate testing components, Programmable capabilitieseasy keypad interface directs independent control of up to three separate test baskets. var addy1925c8664e745e851437e17dd97a6ae6 = 'sales.usa' + '@'; Through the principle of magnetic induction, a copper ring built into the disk placed above each tablet enables instantaneous tracking of changes in product height during each stroke. Glass Replacement Tubes for 6 Tube Disintegration Assembly for Erweka Testers, 24mm OD x 78mm L (Set/6) QLA Part Number: DISTUB-EW Equivalent to OEM Part Number: Erweka 502-310-0001 Fits Bath Models: Erweka Cert of Compliance: Yes Color: Glass Replacement Tubes for 6 Tube Disintegration Assembly for Hanson Testers, 25mm OD x 79.5mm L (Set/6) QLA Part Number: DISTUB-HR06. var addy_textbfa42b8edb5e9785a4b5de5c8462e3a2 = 'sales' + '@' + 'erweka' + '.' + 'ru';document.getElementById('cloakbfa42b8edb5e9785a4b5de5c8462e3a2').innerHTML += ''+addy_textbfa42b8edb5e9785a4b5de5c8462e3a2+'<\/a>'; Flat A 11/F Man Lok Bldg. You need JavaScript enabled to view it. You must have JavaScript enabled in your browser to utilize the functionality of this website. Analytical cookies are used to understand how visitors interact with the website. It is important to maintain the proper tubing lengths between components. Phone: +85 2940 13155E-Mail: This email address is being protected from spambots. The result of decades of innovation and experience in the field of pharmaceutical testing, the DTGi Series of disintegration testers from Copley simplifies testing within R&D and QC environments. var path = 'hr' + 'ef' + '='; Automated Hardness, Thickness, Weight Testing, Complete Basket Assemblies with sample tubes and fluted disks, USP Apparatus "B" Three sample baskets described for larger tablets and supplements, Special screen mesh tops for soft and hard gelatin capsules, Different mesh size tops and basket bottoms. Each product tested can be traced via its batch ID number. Designed for accuracy, intelligent automation, and high productivity, the SmartBasket connects and disconnects instantly by means of a magnetic coupling that aligns itself automatically to the center line of each beaker. Sophisticated AutoSense technology automatically detects the disintegration of each tablet. Eur./USP provided as standard, Comprehensive IQ/OQ/PQ documentation packages and toolkits available, Passcode-protected single-point electronic temperature calibration, Latest temperature calibration information stored and available to print/export. You also have the option to opt-out of these cookies.

The user friendly ZT 320 series comes with one to four individually operated test stations, each connected to an individual keypad for easy setting of the required run time parameters as well as to start and stop the operation.

Suitable for a wide range of tablet and capsule types (e.g. QLAs Disintegration Accessories areUSP compliant and compatible with Agilent/VanKel Disintegration Baths. Available in two-position and four-position models, each position can be programmed and operated independently, allowing up to four different products to be tested simultaneously. Necessary cookies are absolutely essential for the website to function properly. var path = 'hr' + 'ef' + '='; Teledyne Instruments, Inc. All Rights Reserved. 10 mesh Cover for 3 tube disintegration assembly, 316 SS, VanKel/Agilent and Distek compatible QLA Part Number: DISASY-03COV10 Fits Bath Models: Agilent: VK100 Disintegration Distek Material: 316 SS Screen Mesh: 10 UOM/Pack Size: EACH 10 mesh Cover for 6 tube disintegration assembly, 316 SS, VanKel/Agilent and Distek compatible QLA Part Number: DISASY-06COV10 Fits Bath Models: Agilent: VK100 Disintegration Distek Material: 316 SS Screen Mesh: 10 UOM/Pack Size: EACH, 100 Mesh SS Screens for 6 Tube Disintegration Assembly (Set/6) QLA Part Number: DISSCR-VK100 Fits Bath Models: Agilent: VK100 Disintegration Material: 316 SS Screen Mesh: 100 UOM/Pack Size: SET/6, 1000mL Clear Glass Disintegration Beaker with Flared Top for Distek Disintegration Model 3100 QLA Part Number: GLA900-DBDK Equivalent to OEM Part Number: Distek 3010-0360, 20 Mesh SS Screens for 6 Tube Disintegration Assembly (Set/6) QLA Part Number: DISSCR-VK20 Fits Bath Models: Agilent: VK100 Disintegration Material: 316 SS Screen Mesh: 20 UOM/Pack Size: SET/6, 40 Mesh SS Screens for 6 Tube Disintegration Assembly (Set/6) QLA Part Number: DISSCR-VK40 Fits Bath Models: Agilent: VK100 Disintegration Material: 316 SS Screen Mesh: 40 UOM/Pack Size: SET/6, Glass Replacement Tubes for 3 Tube Disintegration Assembly for Hanson Testers, 38mm OD x 80mm L (Set/6) QLA Part Number: DISTUB-HR03.

Sitemap 15

disintegration tester parts関連記事

  1. disintegration tester partscrown royal apple logo

  2. disintegration tester partsbomaker gc355 bluetooth

  3. disintegration tester partsgiandel inverter reset

  4. disintegration tester partsbest black spray paint for glass

  5. disintegration tester partsjam paper gift bows super tiny

  6. disintegration tester partsdick's women's chacos

disintegration tester partsコメント

  1. この記事へのコメントはありません。

  1. この記事へのトラックバックはありません。

disintegration tester parts自律神経に優しい「YURGI」

PAGE TOP